Binary Gradient Systems

Examples of binary gradient systems with control- and analysis software.
(Each system can be upgraded with pumps or detectors)

DGS-200
Model DGS-200 Automated Binary Gradient. Includes: Variable Wavelength Detector for 185-800 nm Operation D2 Lamp D2 Lamp (185-360 nm; to 800 nm with optional W lamp); Model DPM-200 Gradient Pump Module with Pressure Transducer, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Star-Chrom HPLC Management Software and Accessories with Calibration Module. Stainless Steel or PEEK Construction.

DGS-200 FL
Model DGS-200 FL Automated Binary Gradient. Includes: Fluorescence Detector; Model DPM-200 Gradient Pump Module with Pressure Transducer, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Star-Chrom HPLC Management Software and Accessories with Calibration Module. Stainless Steel or PEEK Construction.

DGS-200 CD
Model DGS-200 CD Automated Binary Gradient. Includes: Conductivity Detector; Model DPM-200 Gradient Pump Module with Pressure Transducer, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Star-Chrom HPLC Management Software and Accessories with Calibration Module. PEEK Construction.

DGS-200 DW
Model DGS-200 DW Automated Binary Gradient. Includes: Dual Wavelength Detector; Model DPM-200 Gradient Pump Module with Pressure Transducer, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Star-Chrom HPLC Management Software and Accessories with Calibration Module. Stainless Steel or PEEK Construction.

Note: The systems are shown with the CAM module. The CAM module will be available soon.

Column Accessory Module (CAM) includes: Through-the- Handle Injection Valve, Solvent Degasser, Column Oven. Stainless Steel or PEEK Construction.
Models:
DGS-200
Detector: UV/VIS Detector, var. wavelength 185-800 nm D2 and W lamp
Pump module: 0.01 – 9.99 ml/min, Pressure max. 2500 PSI
Stainless Steel or PEEK
Software: Starchrome, 2 control and data channels each
Upgradeable: quaternary gradient system with second detector
DGS-200 P
Pump module: Stainless Steel,
Pressure max. 5000 PSI
Otherwise like DGS-200
DGS-200 FL
Detector: FluoreszenzDetector mit festen Wellenlängen (Filter)
254 nm / >420 nm und weitere Kombinationen
sonst wie DGS-200
DGS-200 CD
Detector: Conductivity detector
Otherwise like DGS-200
DGS-200 DW
Detector: Two channel UV/VIS detector
wavelength combination:
214 nm and 280 nm, D2 lamp
440 nm and 570 nm, W lamp
Otherwise like DGS-200
Other configurations avaiable on request
x