Isocratic Systems
Examples of isorcatic systems with software(Each system can be complemented with pumps and detectors))

Model DLC-10 PLUS. A DLC-10C Isocratic HPLC System with Fixed Wavelength Detector for 254 nm Operation. Through-the-Handle Injection Valve (TtH) with Position Sensor, and Pressure Read-out Capability, pump flow 0.01-9.99 ml/min, 2500 psi, PEEK or Stainless Steel Construction. Also includes: Star-Chrom LITE PLUS one-channel data acquisition software and Calibration Module with pump control. This is built into the case for a convenient single box HPLC system. Requires: User supplied computer: minimum 166MHz Pentium Computer with One available COM Port (RS-232), Windows 98/XP, or NT/2000 Operating System. Can not be upgraded to gradient.
DIS-10/11.
(Equal to DLC-10-Plus) This offers two channel data acquisition and control. Includes a Through-the-Handle Injection Valve. May be upgraded to binary gradient with optional pump.

Isocratic HPLC System with Variable Wavelength Detector for 195-800 nm Operation D2 Lamp (195-360 nm; to 800 nm with optional W lamp), 10 µl Analytical Flowcell, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Pressure Read-out Capability. Pump flow 0.01-9.99 ml/min, 2500 psi. Stainless Steel Construction.
Also includes: Star-Chrom two channel data acquisition software and Calibration Module, with wavelength and pump control. Configured for 230VAC, 50/60Hz. Includes D2 Lamp, Accessory Kit and Power Cord.
Requires User supplied computer. Minimum requirements:
166MHz Pentium Computer with One available COM Port (RS-232), Windows 98/XP or NT/2000 Operating System.
All stack versions of systems are available with alternative detectors (example: DIS-20S FL with fluorescence detector). May be upgraded to binary gradient with optional pump.
Models: | |
DLC-10-PLUS | |
Detectors: | UV/VIS detector with a fixed wavelength (254 nm or others) |
Pump: |
0.01 – 9.99 ml/min, pressure max 2500 PSI Flow path optional PEEK or SS |
Software: | StarchromeLite Plus, one control- and data channel |
DIS-10/11 | |
Detectors: | UV/VIS detector with a fixed wavelength (254 nm or others) |
Pump: |
0.01 – 9.99 ml/min, pressure max 2500 PSI Flow path optional PEEK or SS |
Software: |
Starchrome, two control- and data channels |
Upgradeable: | to a binary gradient system with two detectors |
DIS-10/11P | |
Pump: |
Pressure max 5000 PSI Flow path SS |
Otherwise equal to DIS-10/11 | |
DLC-20S-PLUS | |
Detector: | UV/VIS detector var. wavelength 185 nm – 800 nm |
Light source: | D2 lamp or W lamp |
Pump: |
0.01 – 9.99 ml/min, Pressure max 2500 PSI Flow path optional PEEK or SS |
Software: | StarchromLite Plus, one control- and data channel |
DLC-20S-PLUS FL | |
Detector: |
Fluorescence detector with fixed wave length (filter) 254 nm / >420 nm and other combinations |
Otherwise equal to DLC-20S-PLUS | |
DIS-20S | |
Detector: |
UV/VIS detector, var. wave length 185 nm – 800 nm D2 lamp or W lamp |
Pump: |
0.01 – 9.99 ml/min, pressure max 2500 PSI Flow path optional PEEK or SS |
Software: | Starchrome, two control- and data channel |
Upgradeable | to a binary gradient system with two detectors |
DIS-20SP | |
Pump: |
Flow path SS Pressure max. 5000 PSI |
Otherwise equal to DIS-20S | |
DIS-20S FL | |
Detector: |
Fluorescence detector with fixed wavelength (filter) 254 nm / >420 nm and other combinations |
Otherwise equal to DIS-20S | |