Isocratic Systems

Examples of isorcatic systems with software
(Each system can be complemented with pumps and detectors))

DLC-10-PLUS.
Model DLC-10 PLUS. A DLC-10C Isocratic HPLC System with Fixed Wavelength Detector for 254 nm Operation. Through-the-Handle Injection Valve (TtH) with Position Sensor, and Pressure Read-out Capability, pump flow 0.01-9.99 ml/min, 2500 psi, PEEK or Stainless Steel Construction. Also includes: Star-Chrom LITE PLUS one-channel data acquisition software and Calibration Module with pump control. This is built into the case for a convenient single box HPLC system. Requires: User supplied computer: minimum 166MHz Pentium Computer with One available COM Port (RS-232), Windows 98/XP, or NT/2000 Operating System. Can not be upgraded to gradient.

DIS-10/11.
(Equal to DLC-10-Plus) This offers two channel data acquisition and control. Includes a Through-the-Handle Injection Valve. May be upgraded to binary gradient with optional pump.


DIS-20S.
Isocratic HPLC System with Variable Wavelength Detector for 195-800 nm Operation D2 Lamp (195-360 nm; to 800 nm with optional W lamp), 10 µl Analytical Flowcell, Through-the-Handle Injection Valve (TtH) with Position Sensor, and Pressure Read-out Capability. Pump flow 0.01-9.99 ml/min, 2500 psi. Stainless Steel Construction.
Also includes: Star-Chrom two channel data acquisition software and Calibration Module, with wavelength and pump control. Configured for 230VAC, 50/60Hz. Includes D2 Lamp, Accessory Kit and Power Cord.
Requires User supplied computer. Minimum requirements:
166MHz Pentium Computer with One available COM Port (RS-232), Windows 98/XP or NT/2000 Operating System.

All stack versions of systems are available with alternative detectors (example: DIS-20S FL with fluorescence detector). May be upgraded to binary gradient with optional pump.

Models:
DLC-10-PLUS
Detectors: UV/VIS detector with a fixed wavelength (254 nm or others)
Pump: 0.01 – 9.99 ml/min, pressure max 2500 PSI
Flow path optional PEEK or SS
Software: StarchromeLite Plus, one control- and data channel
DIS-10/11
Detectors: UV/VIS detector with a fixed wavelength (254 nm or others)
Pump: 0.01 – 9.99 ml/min, pressure max 2500 PSI
Flow path optional PEEK or SS
Software: Starchrome, two control- and data channels
Upgradeable: to a binary gradient system with two detectors
DIS-10/11P
Pump: Pressure max 5000 PSI
Flow path SS
Otherwise equal to DIS-10/11
DLC-20S-PLUS
Detector: UV/VIS detector var. wavelength 185 nm – 800 nm
Light source: D2 lamp or W lamp
Pump: 0.01 – 9.99 ml/min, Pressure max 2500 PSI
Flow path optional PEEK or SS
Software: StarchromLite Plus, one control- and data channel
DLC-20S-PLUS FL
Detector: Fluorescence detector with fixed wave length (filter)
254 nm / >420 nm and other combinations
Otherwise equal to DLC-20S-PLUS
DIS-20S
Detector: UV/VIS detector, var. wave length 185 nm – 800 nm
D2 lamp or W lamp
Pump: 0.01 – 9.99 ml/min, pressure max 2500 PSI
Flow path optional PEEK or SS
Software: Starchrome, two control- and data channel
Upgradeable to a binary gradient system with two detectors
DIS-20SP
Pump: Flow path SS
Pressure max. 5000 PSI
Otherwise equal to DIS-20S
DIS-20S FL
Detector: Fluorescence detector with fixed wavelength (filter)
254 nm / >420 nm and other combinations
Otherwise equal to DIS-20S
DIS-20S CD
Detector: Conductivity detector
Otherwise equal to DIS-20S
Other configurations available on request